- PVDF (Hydrophilic/Hydrophobic) syringe filters
- Regenerated cellulose(RC) syringe filters
- Cellulose acetate syringe filters
- Glass fiber (GF) syringe filters
- PTFE (Hydrophobic and Hydrophilic) syringe filters
- Nylon syringe filters
- PES syringe filters — Ion chromatography (IC) certified
Superior membrane quality for HPLC. Hydrophilic PVDF syringe filters do not require pre-wetting for use with aqueous samples. Hydrophobic PVDF filters require pre-wetting with an alcohol before use with aqueous samples.
• Low non-specific binding with exceptional chemical resistance
• Hydrophilic membrane provides excellent flow rates and low binding coefficients
• Certified for chromatographic performance
• Compatible with a wide range of aqueous and organic-based sample environments
• Recommended for HPLC and UHPLC. PVDF syringe filters have a well defined pore structure, giving effective retention of particles without excessive pore blockage. Compatible with aqueous and most organic solvents. They are excellent general filters for HPLC andorga.
Applications:
- HPLC and organic solvent sample preparation and clean up
- Proteinbased samples with high non-specific binding
- Environmental water samples
Specifications:
Membrane: | HPLC certified PVDF(Hydrophilic/Hydrophobic) |
Max. operating temperature: | <100 °C |
Housing: | Medical grade, virgin polypropylene |
Pore Size: | 0.22 µm, 0.45 µm |
Chemical Incompatibilities: | DMF, DMSO, MEK, acetone and most caustic solutions > 6N |
Superior chemical resistance, optimized for biological sample recoveries .
• Hydrophilic membrane provides excellent flow rates and extremely low binding coefficients
• Superior choice for biological assays, gel capsule dissolution testing, protein sample matrixes
• Compatible with a wide range of aqueous and organic-based sample environments
• Recommended for reverse phase and normal phase HPLC. Regenerated cellulose syringe filters are ideally suited for almost any laboratory
procedure,from HPLC sample preparation to dissolution sample testing. Regenerated cellulose possesses superior chemical resistance in either
aqueous or organ- ic-based sample environments. Its extremely low biological-based binding coefficient is ideally suited for maximum sample recoveries of biologi- cal-based assays. Regenerated cellulose contains no binders, surfactants or wetting agents to assure minimal extractables in analytical procedures.
Applications:
• HPLC and organic solvents ample preparation and cleanup
• Dissolution sample analysis, especially high-binding tablets or capsules
• Protein-based samples with high non-specificbinding
• Sample analysis which require maximum recoveries
• Analysis requiring low non-specific binding overawide pH range.
Specifications:
Membrane: | HPLC certified Cellulose acetate |
Max. operating temperature: | <100 °C |
Housing: | Medical grade, virgin polypropylene |
Pore Size: | 0.22 µm , 0.45 µm |
Chemical Incompatibilities: | Sulfuric acid , hydrochloric acid , phosphoric acid or nitric acid > 25%, DMF, phenol |
For filtering of aqueous solutions or biological samples.
• Hydrophilic membrane provides excellent flow rates and extremely low protein-binding coefficients
• Superior choice for biological assays, gel capsule dissolution testing, protein sample matrixes
• Recommended for aqueous HPLC A physically strong membrane which can be used with heated liquids.
Applications:
• Protein-based samples with high non-specific binding
• Sample analysis which require maximum recoveries
Specifications:
Membrane: | Binder free Glass fiber |
Max. operating temperature: | <100 °C |
Housing: | Medical grade, virgin polypropylene |
Pore Size: | 0.22 µm, 0.45 µm |
Chemical Incompatibilities: | Acids, NaOH, dichloromethane, chloroform,ketones, DMSO, THF |
• For large particulate removal.
• Increased sample throughput
• Low extraction neutral borosilicate glass
• For use with viscous or particle-laden samples GMF filters are available in a range of porosities.
Applications:
• Clarification
• Pre-filtering of suspensions
Specifications:
Membrane: | Binder free Glass fiber |
Max.operating temperature: | <100°C |
Housing: | Medical grade,virgin polypropylene |
Pore Size: | 0.22µm,0.45µm |
Chemical Incompatibilities: | Limited resistance with ammonia, NaOH and KOH solutions |
- Excellent chemicalresistance for use with organic matrices
- Excellent flowrates and high loading capacities
- Exceptional temperature stability
- Organic solvent recommended
- Hydrophilic PTFE can be used for the same application but no pre-wetting of the membrane is required . PTFE syringe filters are applicable for filtration of gaseous or organic solvent-based samples. Both membrane types exhibits broad chemical resistance and unsurpassed temperature stability to address
aggressive sample matrixes and extreme temperature situations. The hydrophobic PTFE filter can be utilized as a moisture barrier in venting applications.
PTFE hydrophobic membranes require pre-treatment with alcohol before being suitable for aqueous or high aqueous/organic samples. Do not use directly with aqueous solutions.
Applications:
- HPLC and organic solvent sample preparation and clean up
- Dissolution sample analysis
- General sample preparation prior to analytical analysis
- Elevated temperature samples, caustic or acidic solutions
Specifications:
Membrane: | PTFE (Hydrophobic and Hydrophilic) |
Max. operating temperature: | <100 °C |
Housing: | Medical grade, virgin polypropylene |
Pore Size: | 0.22 µm, 0.45 µm, 1.0µm.... |
Chemical Incompatibilities: | • Perchloric acid • Methylene chloride (limited exposure) • Dioxane, DMF, formic acid > 50% • Aqueous-based sample matrix (unless filter is pre-wetted with an alcohol) |
Naturally hydrophilic with broad chemical resistance
. Excellent flow rates and high-throughput loading
. HPLC recommended
Hydrophilic nylon is extremely well suited for aqueous or organic sample preparation and HPLC, GC or dissolution sample analysis. Due to its excellent
flow characteristics and mechanical stability, nylon offers the best combination of physical parameters to meet the most stringent analytical needs.
Applications:
. HPLC and organic solvent sample preparation and clean up
. Dissolution sample analysis
. General sample preparation prior to analytical analysis
. Mixed sample matrix of aqueous or organic dissolved analytes
Specifications:
Membrane: | HPLC certified nylon |
Max. operating temperature: | <100 °C |
Housing: | Medical grade, virgin polypropylene |
Pore Size: | 0.22 µm, 0.45 µm, 1.0µm.... |
Chemical Incompatibilities: | . Perchloric acid . Methylene chloride (limited exposure) . Dioxane, DMF, formic acid > 50% . Aqueous-based sample matrix (unless filter is pre-wetted with an alcohol) |
Precise results in sensitive analysis of ionic analytes.
• Certified for low-level IC interference by ICP analysis
• Hydrophilic membrane provides excellent flow rates and low binding coefficients
• Low affinity for binding drugs, ideal for dissolution testing procedures
This hydrophilic polymer has excellent cleanliness and is compatible with a wide range of solvents. It is the membrane of choice for ion chro
matography applications.
Applications:
• IC sample preparation and analysis
• Dissolution testing
Specifications:
Membrane: | IC Certified PES |
Max. operating temperature: | <100 °C |
Housing: | Medical grade, virgin polypropylene |
Pore Size: | 0.22 µm, 0.45 µm |
Chemical Incompatibilities: | • Protein-based samples in aqueous solutions • Concentrated acids, chloromethane, chloroform, hexane, acetone, MEK, THF, DMSO |
Related products
- ORIENTFILTR TECHNOLOGY CO.,LTD
- No. 688, Xingfu Road, Chongchuan District, Nantong, Jiangsu, China. 226007
- Email: info@orientfiltr.com
- Phone: 800-293-3858